Under fan laws, constant-wheel-diameter fans experience pressure variation as________________?
Show answer Hide answer
Answer: B. square of fan speed
Explanation
Fan laws dictate that for a constant impeller wheel diameter, generated pressure varies directly as the square of speed. Doubling the rotational speed of a centrifugal fan increases the resulting pressure rise by a factor of four. This quadratic speed relationship stems from fluid acceleration and centrifugal force equations in turbomachinery. Turbomachinery performance scaling relies on dimensionless similarity parameters and fan affinity laws. Impeller tip speed increases linearly with rotational speed, driving higher dynamic pressure generation. Power consumption for constant wheel diameter fans varies as the cube of the rotational speed.
Variable frequency drives adjust fan motor speeds to control ventilation pressure and airflow in buildings. Engineers use fan laws to predict how increasing fan RPM will affect duct system static pressures. Industrial exhaust systems require careful speed selection because power demands rise rapidly with speed. Varying directly as fan speed describes airflow capacity rather than pressure rise performance. Cube of fan speed describes power consumption scaling rather than the quadratic pressure variation. Square root of fan speed is incorrect because pressure increases quadratically, not sub-linearly, with speed.
- Subject
- Engineering
- Category
- Mechanical Engineering
- Topic
- —
- Difficulty
- medium
Related questions
Q1. According to fan laws, holding pressure constant results in speed, capacity, and power varying_________________?
Show answer Hide answer
Answer: B. inversely as square root of density
When holding pressure constant, fan speed and capacity vary inversely as the square root of gas density. Changes in ambient air density require speed adjustments to maintain identical static pressure outputs. Aerodynamic...
Q2. Which material demonstrates the highest thermal conductivity________________?
Show answer Hide answer
Answer: D. copper
Copper has the highest thermal conductivity of these metals, at around 400 watts per metre-kelvin. Aluminium follows at roughly 235, then brass, then steel, with lead the poorest. Copper's combination of thermal and elec...
Q3. An axial flow pump should be initiated with its discharge valve________________?
Show answer Hide answer
Answer: B. kept fully open
Axial flow pumps draw maximum electrical starting torque when their discharge valves are closed. Starting with the discharge valve fully open minimizes starting torque and motor overload. This operational procedure prote...
Q4. Francis turbines are ideally applied for_____________________?
Show answer Hide answer
Answer: A. medium head application from 24 to 180 m
Francis turbines are reaction turbines ideally suited for medium head hydroelectric installations from 24 to 180 meters. Their inward flow runner design efficiently extracts energy from moderate water pressures and flow...
Q5. A centrifugal pump ought to be started with its discharge valve __________________?
Show answer Hide answer
Answer: A. kept fully closed
Centrifugal pumps are started with the discharge valve fully closed to minimize starting torque. Closing the discharge valve reduces the volumetric flow rate to zero, lowering starting power demand. Starting against a cl...
Q6. When starting an axial flow pump, the delivery valve position should be____________________?
Show answer Hide answer
Answer: B. open
Axial flow pump power consumption peaks sharply when the discharge delivery valve is closed. Opening the delivery valve during startup prevents excessive motor current overload conditions. This hydraulic characteristic i...