Question no. 13210

The operational range of a constant volume hydrogen gas thermometer is _____________ °C?

Select your answer for: The operational range of a constant volume hydrogen gas thermometer is _____________ °C?
Show answer

Answer: B. 0 to 100

Explanation

The operational range of a constant volume hydrogen gas thermometer is 0 to 100 degrees Celsius. Hydrogen gas obeys ideal gas laws closely within this specific temperature calibration span. Keeping volume constant allows precise temperature determination by measuring corresponding pressure changes. Constant volume gas thermometers relate absolute temperature directly to gas pressure via Charles law. Hydrogen gas remains stable and resists condensation across the standard 0 to 100 degree Celsius range. Precise manometric scales measure pressure changes corresponding to thermal expansion of the gas.

Primary temperature calibration laboratories use constant volume gas thermometers to establish reference standards. The 0 to 100 degree Celsius span covers the fundamental ice and steam calibration reference points. Understanding gas thermometer limits ensures accurate fundamental temperature scale realizations. A range of minus 10 to 20 degrees Celsius is too narrow and fails to utilize standard calibration points. Ranges of 100 to 500 degrees Celsius exceed standard hydrogen gas thermometer calibration limits safely. Ranges of 400 to 1000 degrees Celsius require nitrogen or helium gases rather than standard hydrogen.

Subject
Engineering
Topic
—
Difficulty
medium

Related questions

Q1. The degree of freedom of a process denotes the _______________ quantity of controllers required?

Select your answer for: The degree of freedom of a process denotes the _______________ quantity of controllers required?
Show answer

Answer: A. The maximum

The degree of freedom of a process denotes the maximum quantity of controllers required for regulation. Degrees of freedom analysis determines how many independent variables must be manipulated to control a system. This...

Q2. The reference points, namely the ice point and steam point, on the Reaumer temperature scale are respectively_________________?

Select your answer for: The reference points, namely the ice point and steam point, on the Reaumer temperature scale are respectively_________________?
Show answer

Answer: B. 0° & 80°

René Réaumur established a thermometric scale where water freezes at zero degrees Réaumur. On this same historical scale, the boiling point of water under standard pressure is set at 80 degrees. These two fixed equilibri...

Q3. Absolute pressures of 0.01 psi are measurable using a ______________ gauge?

Select your answer for: Absolute pressures of 0.01 psi are measurable using a ______________ gauge?
Show answer

Answer: C. Mcleod

Absolute pressures of 0.01 psi are measurable using a McLeod gauge in high vacuum systems. This instrument compresses trapped gas samples to magnify tiny pressure differences into readable liquid columns. Such high-vacuu...

Q4. A Pirani gauge is deployed to measure________________?

Select your answer for: A Pirani gauge is deployed to measure________________?
Show answer

Answer: B. High vacuum

A Pirani gauge is deployed to measure high vacuum levels accurately in closed industrial systems. It measures the thermal conductivity of a heated filament surrounded by the low-pressure test gas. As vacuum levels increa...

Q5. An absolute pressure of 0.0001 psi can be quantified by a _____________ gauge?

Select your answer for: An absolute pressure of 0.0001 psi can be quantified by a _____________ gauge?
Show answer

Answer: A. Mcleod

The McLeod gauge compresses a known volume of low-pressure gas to measure high vacuum accurately. Applying Boyle's law allows this instrument to quantify extremely low absolute pressures like 0.0001 psi. Its mechanical c...

Q6. The Routh stability criterion employs the ______________ loop transfer function?

Select your answer for: The Routh stability criterion employs the ______________ loop transfer function?
Show answer

Answer: B. Closed

The Routh stability criterion employs the characteristic equation derived from the closed-loop transfer function. By analyzing the coefficients of this polynomial denominator, stability is determined without solving root...