Skip to main content
Sign in Register
Question no. 13213

An absolute pressure of 0.0001 psi can be quantified by a _____________ gauge?

Select your answer for: An absolute pressure of 0.0001 psi can be quantified by a _____________ gauge?
Show answer

Answer: A. Mcleod

Explanation

The McLeod gauge compresses a known volume of low-pressure gas to measure high vacuum accurately. Applying Boyle's law allows this instrument to quantify extremely low absolute pressures like 0.0001 psi. Its mechanical compression principle makes it a primary standard instrument for high vacuum measurement. Absolute pressure represents force per unit area measured relative to a complete vacuum. Measuring ultra-low pressures requires specialized techniques to overcome molecular friction and leakage. The McLeod gauge uses mercury columns to trap and compress the sampled gas sample.

High vacuum environments are essential in semiconductor manufacturing, mass spectrometry, and distillation. Accurate vacuum measurement prevents contamination and ensures proper operation of specialized equipment. Industrial vacuum systems rely on dependable gauges to monitor seal integrity and pumping efficiency. Pirani gauges measure vacuum by detecting thermal conductivity changes in heated wire filaments. Thermocouple gauges infer low pressures by measuring temperature variations of a heated sensor element. Saying none of these is incorrect because the McLeod gauge is specifically suited for this task.

Subject
Engineering
Topic
—
Difficulty
medium

Related questions

Q1. The reaction of a linear control system to a set point variation is termed __________________?

Select your answer for: The reaction of a linear control system to a set point variation is termed __________________?
Show answer

Answer: C. Servo problem

A servo problem in control engineering specifically deals with tracking changes in the reference input. When an operator adjusts the set point, the control system executes a servo response to match it. This contrasts wit...

Q2. The operational range of a constant volume hydrogen gas thermometer is _____________ °C?

Select your answer for: The operational range of a constant volume hydrogen gas thermometer is _____________ °C?
Show answer

Answer: B. 0 to 100

The operational range of a constant volume hydrogen gas thermometer is 0 to 100 degrees Celsius. Hydrogen gas obeys ideal gas laws closely within this specific temperature calibration span. Keeping volume constant allows...

Q3. A platinum resistance thermometer functions up to the antimony point, which is ____________ °C, defined as the equilibrium temperature between solid and liquid antimony at standard atmospheric pressure?

Select your answer for: A platinum resistance thermometer functions up to the antimony point, which is ____________ °C, defined as the equilibrium temperature between solid and liquid antimony at standard atmospheric pressure?
Show answer

Answer: B. 630.74

The antimony point is internationally recognized as a secondary temperature fixed point for calibration. This standardized calibration point corresponds precisely to the freezing temperature of pure antimony metal. Preci...

Q4. The silver point temperature is registered at ______________ °C?

Select your answer for: The silver point temperature is registered at ______________ °C?
Show answer

Answer: C. 960.5

The silver point is a recognized international temperature scale calibration reference point. It represents the exact equilibrium freezing temperature of pure silver at standard atmospheric pressure. Metrological definit...

Q5. Pick out the accurate statement from the choices below?

Select your answer for: Pick out the accurate statement from the choices below?
Show answer

Answer: C. The amplitude ratio of a pure capacity process is inversely proportional to frequency

For a pure capacity process, the amplitude ratio is inversely proportional to the frequency of the input. As input frequency increases, the ability of a pure capacity process to track oscillations diminishes rapidly. Mat...

Q6. The connection between heat evolution or absorption at thermocouple junctions and circuit current is described by the _____________ effect?

Select your answer for: The connection between heat evolution or absorption at thermocouple junctions and circuit current is described by the _____________ effect?
Show answer

Answer: A. Peltier

The Peltier effect involves the absorption or generation of heat when electrical current crosses junctions. Passing a direct current through a thermocouple circuit causes one junction to cool and another to warm. This th...