Skip to main content
Sign in Register
Question no. 27276

Why is direct line-starting discouraged for induction motors in favor of starters__________?

Select your answer for: Why is direct line-starting discouraged for induction motors in favor of starters__________?
Show answer

Answer: A. motor takes five to seven times its full load current

Explanation

At standstill, zero rotor speed creates maximum slip and high transformer action currents. Connecting the motor directly to the line draws massive starting current surges. These high currents typically range between five and seven times normal full load values. Direct-on-line starting applies full line voltage instantly to stationary motor stator windings. High starting currents can cause severe voltage sags across local electrical distribution systems. Windings must be thermally robust to withstand high starting current surges without failing.

Starters and variable frequency drives are mandatory for large motors to limit starting current. Electrical utilities enforce strict current limits on industrial motor startups to protect grids. Small fractional horsepower motors are often the only units permitted for direct-on-line starting. Option b is incorrect because motors accelerate smoothly rather than going out of step instantly. Option c is incorrect because phase sequence determines rotation direction, not starting method. Option d is incorrect because starting torque is often relatively low despite high current draw.

Subject
Engineering
Topic
—
Difficulty
medium

Related questions

Q1. What characteristics define the inner cage of a double-cage induction motor__________?

Select your answer for: What characteristics define the inner cage of a double-cage induction motor__________?
Show answer

Answer: A. high inductance arid low resistance

The inner cage of a double-cage motor is buried deep within the rotor iron core lamination slots. Deep slot placement surrounds the inner conductors with more magnetic material, increasing their inductance. Lower resista...

Q2. A 3-phase, 440 V, 50 Hz induction motor operates at 4% slip. What is the frequency of its induced rotor e.m.f____________?

Select your answer for: A 3-phase, 440 V, 50 Hz induction motor operates at 4% slip. What is the frequency of its induced rotor e.m.f____________?
Show answer

Answer: C. 2 Hz

The frequency of induced rotor voltages depends directly on the slip of the motor. Multiplying the supply frequency by the fractional slip yields the exact rotor electrical frequency. Zero point zero four multiplied by f...

Q3. What is the typical slip value of an induction motor running under no-load conditions____________?

Select your answer for: What is the typical slip value of an induction motor running under no-load conditions____________?
Show answer

Answer: A. less than 1%

Under no-load conditions, the motor shaft encounters virtually no mechanical resistance opposing rotation. Without a heavy load, the rotor accelerates to a speed extremely close to the rotating magnetic field. A tiny spe...

Q4. Which performance parameter cannot be evaluated using an induction motor short-circuit test___________?

Select your answer for: Which performance parameter cannot be evaluated using an induction motor short-circuit test___________?
Show answer

Answer: A. windage losses

The short-circuit test applies reduced voltage to a locked rotor to measure copper losses. Windage and friction losses occur only when the rotor is spinning at normal running speeds. A locked rotor cannot produce windage...

Q5. What types of motors are compatible with reduced voltage starters_____________?

Select your answer for: What types of motors are compatible with reduced voltage starters_____________?
Show answer

Answer: C. squirrel cage as well as slip ring induction motor

Reduced voltage starters such as auto-transformers or star-delta starters are applicable to squirrel-cage induction motors.

Q6. What causes low voltage levels at motor terminals____________?

Select your answer for: What causes low voltage levels at motor terminals____________?
Show answer

Answer: C. any one of the above

Poorly regulated power supplies fail to maintain steady voltage levels under fluctuating facility load conditions. Inadequate branch wiring with high electrical resistance creates excessive voltage drops before reaching...