Skip to main content
Sarkari MCQs Government Exam Question Bank
Menu
Question no. 58053

Dissolved moisture circulating in a refrigerant is successfully extracted using___________________?

Select your answer for: Dissolved moisture circulating in a refrigerant is successfully extracted using___________________?
Show answer

Answer: D. driers

Explanation

Driers containing desiccants are installed in refrigeration systems to extract dissolved moisture successfully. Moisture can react with lubricants to form harmful acids that corrode internal compressor parts. Filter driers trap both solid particulate debris and liquid water circulating in the refrigerant lines. Common desiccants used in filter driers include activated alumina and molecular sieve materials. Moisture freezing at the expansion valve orifice can block refrigerant flow entirely. Driers are typically installed in the liquid line ahead of the expansion valve for maximum efficiency.

HVAC technicians replace filter driers during routine maintenance and whenever systems are opened for repair. Preventing moisture contamination extends the operating lifespan of hermetic compressor motors significantly. Reliable moisture control is essential for maintaining dependable operation in sealed refrigeration units. Evaporator is designed for heat absorption rather than extracting moisture from the refrigerant loop. Safety relief valve protects the system from overpressure events rather than filtering contaminants. Dehumidifier removes moisture from room air rather than internal circulating refrigerant fluid.

Subject
Engineering
Topic
—
Difficulty
medium

Related questions

Q1. The normal atmospheric boiling point temperature of ammonia is___________________?

Select your answer for: The normal atmospheric boiling point temperature of ammonia is___________________?
Show answer

Answer: C. – 33.3°C

The normal atmospheric boiling point of ammonia is approximately –33.3°C. At standard atmospheric pressure, liquid ammonia boils and absorbs latent heat at this specific sub-zero temperature. This thermal property makes...

Q2. Decreasing the condenser temperature while keeping the evaporator temperature constant will cause the refrigeration cycle COP to__________________?

Select your answer for: Decreasing the condenser temperature while keeping the evaporator temperature constant will cause the refrigeration cycle COP to__________________?
Show answer

Answer: A. increase

Decreasing the condenser temperature lowers the high-side pressure and work input, thereby increasing the COP of the refrigeration cycle. Lowering the condenser temperature reduces the compressor pressure ratio and decre...

Q3. The net refrigeration effect produced in a dry expansion evaporator versus a flooded evaporator in a similar plant is_________________?

Select your answer for: The net refrigeration effect produced in a dry expansion evaporator versus a flooded evaporator in a similar plant is_________________?
Show answer

Answer: C. less

A dry expansion evaporator provides a lower net refrigeration effect than a flooded evaporator. Dry expansion coils contain vapor refrigerant in the latter portion, reducing active heat transfer. Flooded evaporators keep...

Q4. Standard vapor compression refrigerators operate according to which thermodynamic cycle_________________?

Select your answer for: Standard vapor compression refrigerators operate according to which thermodynamic cycle_________________?
Show answer

Answer: E. Reversed Carnot

Standard vapor compression refrigerators operate on the reversed Carnot cycle as an ideal theoretical upper bound.

Q5. The saturation vapor pressure characteristics of a suitable refrigerant should be_________________?

Select your answer for: The saturation vapor pressure characteristics of a suitable refrigerant should be_________________?
Show answer

Answer: B. higher than atmospheric pressure

A suitable refrigerant should have a saturation vapor pressure higher than atmospheric pressure to prevent air leakage into the system. Operating above atmospheric pressure ensures that any minor flange or valve leak exp...

Q6. Relative coefficient of performance is defined as the ratio of_____________________?

Select your answer for: Relative coefficient of performance is defined as the ratio of_____________________?
Show answer

Answer: A. actual COP/fheoretical COP

Relative coefficient of performance is defined as the ratio of the actual COP to the theoretical Carnot or cycle COP. Comparing actual operating performance against ideal theoretical cycles yields the relative coefficien...

New!

Mock Test System is now available!

Prepare for your exam with interactive mock tests. Select your subjects, attempt 100 random MCQs against the clock, and see exactly where you stand.

Start Mock Test