Question no. 17855

An R.C.C. lintel spans a 2 m opening within a brick wall. With the floor-to-roof height at 2.9 m and the opening top at 2.1 m above the floor, the lintel must be designed to carry its self-weight plus_______________?

Select your answer for: An R.C.C. lintel spans a 2 m opening within a brick wall. With the floor-to-roof height at 2.9 m and the opening top at 2.1 m above the floor, the lintel must be designed to carry its self-weight plus_______________?
Show answer

Answer: C. UDL of wall + load from the roof

Explanation

An R.C.C. lintel beneath a floor-to-roof wall must carry its own dead weight plus the combined UDL of the wall. Walls located below roof levels transmit both their own self-weight and direct vertical loads from the roof structure. The total design load on the lintel therefore combines the continuous wall load and the imposed roof loading. Lintels are horizontal structural beams placed above door and window openings to support masonry walls situated overhead. Load distribution over small wall openings typically follows empirical rules depending on masonry height and roof proximity. Dead loads from walls and roofs must be accurately estimated to ensure adequate structural load paths down to foundations.

Option A assumes a purely triangular masonry load distribution which only applies when walls are very tall and unconstrained. Option B neglects the crucial vertical contribution of roof loads transmitted directly through the upper masonry wall. Option D incorrectly applies a triangular load pattern instead of treating the wall above as a uniform distributed load.

Subject
Engineering
Topic
—
Difficulty
medium

Related questions

Q1. An R.C.C. beam, 25 cm wide and 50 cm in effective depth, has a 6 m clear span and carries a U.D.L. of 3000 kg/m inclusive of self-weight. Given a lever arm constant of 0.865, compute the maximum shear stress intensity_______________?

Select your answer for: An R.C.C. beam, 25 cm wide and 50 cm in effective depth, has a 6 m clear span and carries a U.D.L. of 3000 kg/m inclusive of self-weight. Given a lever arm constant of 0.865, compute the maximum shear stress intensity_______________?
Show answer

Answer: A. 8.3 kg/cm2

Calculating the maximum shear force from the UDL and dividing by the web width gives the shear stress intensity. Multiplying the total UDL by half the clear span yields the maximum shear force acting at the support. Divi...

Q2. Under I.S. : 456 specifications, the safe diagonal tensile stress permitted for M 150 grade concrete is_____________?

Select your answer for: Under I.S. : 456 specifications, the safe diagonal tensile stress permitted for M 150 grade concrete is_____________?
Show answer

Answer: A. 5 kg/cm2

Under IS 456 specifications, the safe diagonal tensile stress permitted for M 150 grade concrete is five kilograms per square centimeter. Exceeding this allowable shear stress threshold requires the installation of web r...

Q3. A singly reinforced concrete beam (width 25 cm, effective depth 70 cm) is reinforced with 18.75 cm2 of steel. Assuming a modular ratio m of 15, calculate the depth of the neutral axis_________________?

Select your answer for: A singly reinforced concrete beam (width 25 cm, effective depth 70 cm) is reinforced with 18.75 cm2 of steel. Assuming a modular ratio m of 15, calculate the depth of the neutral axis_________________?
Show answer

Answer: C. 30 cm

Using the modular ratio and equilibrium of compressive and tensile forces, the neutral axis depth calculates to 30 cm. Equating the concrete compressive force area moment to the steel tensile force area moment yields a q...

Q4. An R.C.C. column is designated as a long column when its slenderness ratio exceeds____________?

Select your answer for: An R.C.C. column is designated as a long column when its slenderness ratio exceeds____________?
Show answer

Answer: D. 50

An R.C.C. column is designated as a long column when its slenderness ratio exceeds the code limit of 50. Building design standards explicitly classify compression members based on slenderness ratios to account for buckli...

Q5. An R.C.C. beam of 25 cm width has a 5 m clear span and supports a U.D.L. of 2000 kg/m including self-weight. If the section's lever arm is 45 cm, evaluate whether the beam__________________?

Select your answer for: An R.C.C. beam of 25 cm width has a 5 m clear span and supports a U.D.L. of 2000 kg/m including self-weight. If the section's lever arm is 45 cm, evaluate whether the beam__________________?
Show answer

Answer: A. Safe in shear

Calculating nominal shear stress and comparing it against permissible concrete limits confirms the beam is safe in shear. The applied transverse load generates a shear force that produces stresses lower than the inherent...

Q6. According to I.S. : 456, two-way spanning slabs with held-down corners are divided into middle and edge strips, where the width of the middle strip is stipulated as______________?

Select your answer for: According to I.S. : 456, two-way spanning slabs with held-down corners are divided into middle and edge strips, where the width of the middle strip is stipulated as______________?
Show answer

Answer: C. Three-fourth of the width of the slab

IS 456 requirements for two-way spanning slabs stipulate that the width of the middle strip should be three-fourths. Dividing the slab into middle and edge strips helps in placing bending reinforcement according to varyi...